Country profile

United States (OSHA): noise thresholds

90 dBA PEL · 5 dB exchange · 85 dBA action level

MethodDose method, 5 dB exchange rate
Reference period8 hours
Action level85 dB(A)
Permissible exposure limit90 dB(A)
Criterion level90 dB(A)
Dose threshold80 dB(A)
Shortest time in Table G-16 (15 minutes or less)115 dB(A)
Peak limit140 dB(Z)

Notes

  • 29 CFR 1910.95. Action level 85 dBA TWA starts the hearing conservation program.
  • Table G-16 gives permitted times, down to 15 minutes or less at 115 dBA. The levels included in the dose differ between the PEL and the action level, so check 29 CFR 1910.95 before relying on this profile.
  • Impact or impulse noise limit: 140 dB peak.

Verified: 2026-11. Rules change and local requirements can be stricter, so check the current rules that apply to your workplace.

SonoDose gives an interim check using these values. It is not an assessment under any regulation.