Country profile

United Kingdom: noise thresholds

80 / 85 dB LEP,d · 135 / 137 dB(C) peak

MethodEqual energy, 3 dB exchange rate
Reference period8 hours
Lower action value80 dB(A)
Upper action value85 dB(A)
Exposure limit87 dB(A)
Peak, lower action value135 dB(C)
Peak, upper action value137 dB(C)
Peak limit140 dB(C)

Notes

  • Control of Noise at Work Regulations 2005 values.
  • The exposure limit (87 dB(A), 140 dB(C)) takes hearing protection into account.
  • An interim check is not an assessment under the Regulations.

Verified: 2026-11. Rules change and local requirements can be stricter, so check the current rules that apply to your workplace.

SonoDose gives an interim check using these values. It is not an assessment under any regulation.